Synthes va prox tibia inventory

TomoFix Medial High Tibial Plate (MHT) VA-LCP® MEDIAL COLUMN FUSION PLATES 3.5 VA LOCKING CALCANEAL PLATES 2.7 VA-LCP Ankle Trauma System 2.7/3.5 VA-LCP Anterior Clavicle Plate VA-LCP Condylar Plate 4.5/5.0 VA-LCP Distal Humerus Plates 2.7/3.5 VA-LCP Olecranon Plates 2.7/3.5 VA-LCP Proximal Tibial Plate 3.5

226.622, 226.632, 226.642... View More. PRODUCT CODES. DESCRIPTION. The LCP™ Periprosthetic System consists of key instruments from the Orthopaedic Cable System and uses features like Combi holes and locking compression plates to offer flexibility and stability in fixation of periprosthetic fractures. Product Specifications.Feb 10, 2022 · Results. This study included 144 posterolateral tibial plateau fractures. When not using screws in a variable angle (VA) manner, the fixation effectiveness for posterolateral fragments was 58.3% for the DePuy Synthes locking compression plates (LCP), 47.9% for the DePuy Synthes VA-LCP, 50.7% for the Zimmer plate, and 43.8% for the Biomet plate.

Did you know?

The DePuy Synthes VA-LCP PPFx Proximal Femur Plating System 3.5/4.5/5.0 is con - traindicated for independent fixation if the hip stem requires immediate revision. The DePuy Synthes VA-LCP PPFx Proximal Femur Hook Plate 3.5/4.5/5.0 with 5 holes (shortest plate) is contraindicated for diaphyseal periprosthetic femoralIndIcatIonS the tibial nail- ex is intended to stabilize fractures of the proximal and distal tibia and the tibial shaft, open and closed tibial shaft fractures, certain pre- and postisthmic fractures, and tibial malunions and nonunions. Titanium Cannulated Tibial Nail Expert Nailing System Surgical Technique DePuy Synthes Trauma...DePuy Synthes is a global leader in medical devices for foot and ankle procedures. Our foot and ankle portfolio is the result of working with healthcare professionals around the globe to develop solutions tailored to the needs of both patients and surgeons. We offer comprehensive solutions for foot and ankle reconstruction, elective and trauma ...3.5 mm LCP® Medial Proximal Tibia Plates Surgical Technique DePuy Synthes 1 MR Information The 3.5 mm LCP Medial Proximal Tibia Plate System has not been evaluated for safety and compatibility in the MR environment. It has not been tested for heating, migration or image artifact in the MR environment. The safety of the 3.5 mm LCP Medial

Description. Synthes 8MM TI Cannulated Tibial Nail EX 375MM. Part # 04.004.255S Exp 3/22. The Synthes 8MM TI Cannulated Tibial Nail offers a variety of proximal and distal locking options, giving the surgeon the ability to tailor fixation to the fracture pattern. The Titanium Cannulated Tibial Nail — EX is available in a universal design for ...LCP™ Ulna Osteotomy System (2.7 mm) 02.111.900, 02.111.900S, 02.111.901... The LCP™ Ulna Osteotomy System is a comprehensive system of plates allowing for ulnar shortening osteotomies. The system provides a low profile, angular stable fixation with a choice of two cut styles: transverse (90°) and oblique (45°).pilot hole in the tibia. Drive the tibia screw into the tibia by turning the driver clockwise until it is fl u s h with the lateral tibia wall. Notes: • A n increase in torque indicates that the shoulder of the driver has contacted the lateral cortex of the tibia. • T actile feedback may be more subtle in less dense bone. Precautions:Inventory Control Form 2.7 mm/3.5 mm LCP Distal Fibula Plate System Some devices in this form may not have been licensed in accordance with Canadian law and may not be for sale in Canada. Please contact your sales consultant for items approved for sale in Canada. DISTFIBICF001 05/22 2 Length 206.028 28 mm 206.030 30 mm 206.035206.014 35 mmThe DePuy Synthes 4.5 mm LCP® Condylar Plate is part of the LCP Periarticular Plating System, which merges locking screw technology with conventional plating techniques. The LCP Periarticular Plating System is capable of addressing complex fractures of the distal femur with the 4.5 mm LCP Condylar Plates, complex fractures of the proximal femur

2 DePuy Synthes Placa LCP 3.5 para tibia proximal Técnica quirúrgica La placa LCP 3.5 para tibia proximal forma parte del sistema LCP (Locking Compression Plate, placa de compresión diná-mica) de Synthes para fragmentos pequeños, que combina la técnica de los tornillos de bloqueo con las técnicas tradicio-nales de osteosíntesis con placas.Synthes 11 Instruments for the insertion of LISS Insertion Guide left (324.003) Insertion Guide right, not illustrated (324.004) Pin Wrench (321.170) Fixation Bolt (324.043) …Placa VA-LCP 3.5 para tibia proximal Técnica quirúrgica - Read more about placa, proximal, broca, tibia, tornillos and synthes. Show menu. Buy now. Swipe Vertical Scroll Horizontal Scroll Page Turn View Mode. Share from cover. Share from page. Table of contents. Page Overview. 1 out of 76.…

Reader Q&A - also see RECOMMENDED ARTICLES & FAQs. Under the scan conditions defined above, the DePuy Synthes Tibial Na. Possible cause: Die LCP Mediale Distale Tibiaplatte Low Bend 3.5...

J5294-F 10/12 These implants and instruments are available nonsterile or sterile-packed. Add S to catalog number to order sterile product. Inventory Control Form Titanium Cannulated Humeral Nail-EX System Patient Information: SYNTHES (USA) SYNTHES (Canada) Ltd. To Order: (800) 523-0322 To.The Universal Small Fragment System can support all 2.7 mm/3.5mm non-locking, LCP™ System, and VA LCP™ Locking Technologies. It consists of two components: A core set of instruments, screws, and standard implants. Modular anatomic implant trays for supported small fragment anatomy. Get in Touch with a Sales Consultant.Synthes (USA) Synthes (Canada) Ltd. To Order: (800) 523-0322 To Order: (800) 668-1119 Date: Hospital: Surgeon: Procedure: Implants Patient Information: J7510-C 11/13 Inventory Control Form LCP Distal Femur and LCP Proximal Lateral …

Inventory Control Form TFN-ADVANCED™ Proximal Femoral Nailing System Implants Date: Hospital: Surgeon: Procedure: Case Information (eg, Case ID): TFN-ADVANCEDTM System (TFNA), Long Nails, 9 mm distal diameter, sterile Right Part # Left Part # Length (mm) Femoral Neck Angle 04.037.916S 04.037.917S 260 125° 04.037.918S 04.037.919S …Inventory Control Form Variable Angle LCP Distal Radius Plates 2.4 mm VA LCP Dorsal Distal Radius Plate, Intermediate Column Shaft Holes Length (mm) Angled 02.115.630 3 41 +90° 02.115.631 3 41 –90° 02.115.640 4 49 +90° 02.115.641 4 49 –90° 2.4 mm VA LCP Dorsal Distal Radius L-Plate, 2 holes headSynthes Stainless Steel VA-LCP Small Bend Proximal Tibia Plate, 147 mm Length, 8 Holes, Left Version DEPUY SYNTHES: 02.127.231 The store will not work correctly in the case when cookies are disabled.

beth dutton scar The Arthrex Proximal Tibia Plating System builds on the Titanium Distal Tibia Plating System with the addition of lateral and posteromedial proximal tibia plating options, plateau-specific instruments, and longer screws. All plates accept 4.0 mm fixed-angle locking, 3.5 mm variable-angle locking, and 3.5 mm cortical screws. A T10 driver can be used for all …Inventory Control Form - synthes.vo.llnwd.net. Synthes (USA)Synthes (Canada) Order: (800) 523-0322To Order: (800) 668-1119 Date:Hospital:Surgeon:Procedure:Implants Patient Information:J8493-H 3/13 Inventory Control mm Variable Angle LCP Distal Radius mm VA-LCP Extra-Articular Volar Distal Radius mm VA-LCP Two-Column Volar Distal Radius mm VA-LCP Narrow Two-Column Volar Distal Radius mm VA-LCP ... julius and ethel rosenberg apush definitionheavenly nails ann arbor 3.5 mm LCP Medial Distal Tibia Plates Plate features – natomically contoured; plate is twisted A 20° and bent to fit the distal tibia – vailable for left and right tibias A – imited-contact shaft design with L 4 to 14 combination locking/ compression holes – ight distal locking holes accept E 2.7 mm cortex, 3.5 mm locking, 3.5 mm cortex, or 4.0 mm …Jun 1, 2021 · A – Stryker AxSOS 3 Ti Proximal Tibia plate; B – Smith & Nephew PERI-LOC Lateral Proximal Tibia plate; C – DePuy Synthes 3.5mm Variable Angle Locking Compression Plate [VA-LCP] Proximal Tibia plate – fixed trajectory; D – DePuy Synthes 3.5mm VA-LCP Proximal Tibia plate – VA screws aimed toward the PMF; E – Zimmer Biomet A.L.P.S ... kelsey lawrence and dabb fan bus Variable Angle LCP™ Proximal Tibia Plate (3.5 mm) 02.211.201, 02.211.201S, 02.211.202... Part of the Periarticular Plating System which merges variable angle locking screw technology with conventional plating techniques, this plate provides a fixed-angle construct while allowing surgeons the freedom to choose the screw trajectory before ... michigan i 75 rest areaswebmail cincinnati bellanderson muncie craigslist USF VA LCP ® Proximal Tibial Implant Set 56 USF LCP® Proximal Tibial Implant Set 57 USF VA LCP ® Distal Tibial Implant Set 58 USF LCP® Distal Tibial Implant SetUniversal Small Fragment LCP 59 USF VA LCP ® Distal Fibula Implant Set 60 USF VA LCP ® Distal Fibula with 4.0 mm Cortex Screw Implant Set* 61 USF LCP® Distal Fibula Implant Set 62 ... chaz bono net worth 2021 Titanium Cannulated Tibial Nails-EX, with Proximal bend, sterile Patient Information: J7976-F 5/13 Inventory Control Form Titanium Cannulated Tibial Nail-EX, with Proximal bend 8.0 mm diameter LENGTH LENGTH 04.034.231S 255 mm 04.034.234S 270 mm 04.034.237S 285 mm 04.034.240S 300 mm 04.034.243S 315 mm water temp st petersburg beach floridarotation 180 degrees clockwise about the originabcya andy's golf 2 LCP Periarticular Proximal Humerus Plate 3.5 LCP Posterior Medial Proximal Tibial Plate 3.5 LCP Proximal Femoral Hook Plate 4.5/5.0 LCP Proximal Femoral Plate 4.5/5.0 LCP Proximal Radius Plates 2.4 LCP Proximal Tibial Plate 3.5 LCP Proximal Tibial Plate 4.5/5.0 with Periarticular Aiming Arm Instruments LCP Superior Anterior Clavicle Plate LCP ...O classification 33A and 33C distal femoral fractures were included in the study. Intervention: Internal fixation using only the DePuy-Synthes VA-LCP plate. Main Outcome Measurements: Primary outcomes included mechanical failure rate of the DePuy-Synthes VA-LCP plate in open and closed fractures. Secondary outcomes included overall failure rate of treatment, risk factors for mechanical failure ...